Mass spectrometers
Product listing of various models available in the Indian market, with detailed features, by brand
Brands | Models | Features |
Bruker Daltonics | FT-MS solariX XR | High-end proteomics studies; molecular imaging of tissue; petroleum product analysis; complex environmental sample analysis; metabolomics research |
PerkinElmer | Clarus SQ 8C GC | Offers unsurpassed sensitivity and unparalleled stability for identification and quantitation of volatile and semi-volatile compounds |
Shimadzu Analytical | GCMS-TQ8050 NX | Features a new highly efficient detector and three noise reduction technologies that enable femtogram-level quantitative analysis |
GCMS-TQ8040 NX | First triple quadrupole with smart productivity for high efficiency sample throughput, smart operation for quick and easy method development, and smart performance for low detection limits and scan/MRM | |
GCMS-QP2020 NX | Featuring enhanced instrument functionality, analysis software, databases, and a sample introduction system; Helps maximize the capabilities of the laboratory | |
GCMS-QP2010 SE | Column flow up to 4 mL/min and variety of column selection; Enables direct sample injection and easy expandability without any changes to the GC | |
LCMS-8060NX | The LCMS-8060NX is a triple quadrupole mass spectrometer with world-class sensitivity and detection speeds. Advance features of IonFocus unit, new Analytical Intelligence-derived parameters optimization and new heated ESI design, enhances perfromance, sensitivity and robustness. LCMS-8060NX maximize your laboratory’s output and improves workflow efficiency. | |
LCMS-8060 | Newly developed UF-Qarray ion guide is a groundbreaking technology that increases LC/MS/MS sensitivity by enhancing ion signal intensity and reducing noise; By improving the ion sampling device, the ion guide, and the vacuum efficiency, the LCMS-8060 delivers a new vision of sensitivity and makes a real difference to working better and faster | |
Shimadzu Analytical | DPiMS-8060 | Use both modes by switching easily between ESI and PESI units. Performs MS analysis driectly on sample. With a few steps pretreatment,speedy and easy measurement is possible. |
CLAM-2030 | Fully automated sample preparation module for LCMS® minimizes human error. Increases laboratory efficiency by allowing user to directly place the sample in system | |
LCMS-8050 | Offers high-sensitivity quantitation delivered at high speeds; Rapid multi-component analysis; Simultaneous qualitative and quantitative analyses; Uf scanning at 30,000 u/sec, Uf switching – positive/negative Ionization switching in 5 msec, UF-MRM at 555 ch/sec | |
LCMS-8045 | Shimadzu’s MS interface includes a high-sensitivity heated ESI source, heated capillary sample introduction, and proprietary ion transfer optics; Produce robust MS performance | |
LCMS-8040 | Incorporates newly improved ion optics and collision cell technology to provide higher multiple reaction monitoring (MRM) sensitivity whichyield higher sensitivity for scan mode measurements | |
LCMS-2020 | Ultra high-speed, ultra high-sensitivity MS measurements offers dramatic improvements in lab productivity; With below innovative features in LCMS-2020, the sharp peaks of ultra high-speed LC will not be missed; UF switching (high-speed positive/negative ionization mode switching); UF scanning (high-speed scan measurements); UF sensitivity (superior sensitivity and repeatability thanks to newly developed ion optics) | |
LCMS-9030 Q-TOF LC/MS System |
LCMS-9030 quadrupole time-of-flight (Q-TOF) mass spectrometer integrates the world’s fastest and most sensitive quadrupole technology with TOF architecture. | |
MALDI-TOF Mass Spectrometry | Combines MALDI TOF-TOF mass spectrometry expertise with novel patented technology to provide ultimate performance in identification and structural characterization of biomolecules | |
Thermo Fisher Scientific | Orbitrap Exploris 240 | Discover workhorse versatility from confident proteomic and small-molecule identification and quantitation to biopharmaceutical characterization and in-depth sample-profiling |
FAIMS Pro Duo Interface | Designed for inexperienced users to easily install and use. Leverage online CV optimizaiton routines and menu-driven software to design methods and quickly achieve results | |
Thermo Scientific TSQ Altis/Quantis |
Selectivity – Best performance in the market at 0.4/0.2Da FWHM which shows sensitivity with selectivity; Flexibility – High sample throughput ( multi- channel) and high Performance LC, Ion Chromatography. Suitable for all kind of ionization sources( ESi, APCi, APPi, FAIMS, Duet, Verispray ) Robust and reliable high and non-flow options; Speed – 600 SRMs/sec enables higher throughput! Better performance at lower dwell times! | |
Waters India | SYNAPT G2-Si | Data independent and data dependent solutions; CID and ETD fragmentation capabilities; wide range of experimental options; upgrade to three dimensions of resolution |
Xevo TQ-XS | Triple quadrupole; enhanced detection system with six orders of linear dynamic range to ensure sensitivity | |
Vion IMS QTof | Ion mobility quadrupole TOF mass spectrometry; easier data interpretation as ion mobility cleans up and simplifies every spectrum |